LayerRx Mapping ID
417
Slot System
Featured Buckets
Featured Buckets Admin
Medscape Lead Concept
64500

Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited

Article Type
Changed
Display Headline
Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited

Article PDF
Author and Disclosure Information

Toshiyuki Tateiwa, MD, Ian C. Clarke, PhD, Paul A. Williams, MSc, Jonathan Garino, MD, Masakazu Manaka, MD, Takaaki Shishido, MD, Kengo Yamamoto, MD, PhD, and Atsuhiro Imakiire, MD, PhD

Dr. Tateiwa is Assistant Professor, Department of Orthopaedic Surgery, Tokyo Medical University, Tokyo, Japan.

Dr. Clarke is Director of Peterson Research Center, and Mr. Williams is Research Instructor, Peterson Tribology Laboratory, Orthopaedic Research Center, Department of Orthopaedic Surgery, Loma Linda University Medical Center, Loma Linda, California.

Dr. Garino is Associate Professor, Department of Orthopaedics, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania.

Dr. Manaka is Assistant Professor, Dr. Shishido is Assistant Professor, Dr. Yamamoto is Professor and Chief, and Dr. Imakiire is Former Professor and Chief, Department of Orthopaedic Surgery, Tokyo Medical University, Tokyo, Japan.

Issue
The American Journal of Orthopedics - 37(2)
Publications
Topics
Page Number
E26-E31
Legacy Keywords
ajo, american journal of orthopedics, total hip arthroplasty, tha, ceramic, United States, US, ceramic-on-ceramic, polyethylene, alumina, bearings
Sections
Author and Disclosure Information

Toshiyuki Tateiwa, MD, Ian C. Clarke, PhD, Paul A. Williams, MSc, Jonathan Garino, MD, Masakazu Manaka, MD, Takaaki Shishido, MD, Kengo Yamamoto, MD, PhD, and Atsuhiro Imakiire, MD, PhD

Dr. Tateiwa is Assistant Professor, Department of Orthopaedic Surgery, Tokyo Medical University, Tokyo, Japan.

Dr. Clarke is Director of Peterson Research Center, and Mr. Williams is Research Instructor, Peterson Tribology Laboratory, Orthopaedic Research Center, Department of Orthopaedic Surgery, Loma Linda University Medical Center, Loma Linda, California.

Dr. Garino is Associate Professor, Department of Orthopaedics, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania.

Dr. Manaka is Assistant Professor, Dr. Shishido is Assistant Professor, Dr. Yamamoto is Professor and Chief, and Dr. Imakiire is Former Professor and Chief, Department of Orthopaedic Surgery, Tokyo Medical University, Tokyo, Japan.

Author and Disclosure Information

Toshiyuki Tateiwa, MD, Ian C. Clarke, PhD, Paul A. Williams, MSc, Jonathan Garino, MD, Masakazu Manaka, MD, Takaaki Shishido, MD, Kengo Yamamoto, MD, PhD, and Atsuhiro Imakiire, MD, PhD

Dr. Tateiwa is Assistant Professor, Department of Orthopaedic Surgery, Tokyo Medical University, Tokyo, Japan.

Dr. Clarke is Director of Peterson Research Center, and Mr. Williams is Research Instructor, Peterson Tribology Laboratory, Orthopaedic Research Center, Department of Orthopaedic Surgery, Loma Linda University Medical Center, Loma Linda, California.

Dr. Garino is Associate Professor, Department of Orthopaedics, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania.

Dr. Manaka is Assistant Professor, Dr. Shishido is Assistant Professor, Dr. Yamamoto is Professor and Chief, and Dr. Imakiire is Former Professor and Chief, Department of Orthopaedic Surgery, Tokyo Medical University, Tokyo, Japan.

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 37(2)
Issue
The American Journal of Orthopedics - 37(2)
Page Number
E26-E31
Page Number
E26-E31
Publications
Publications
Topics
Article Type
Display Headline
Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited
Display Headline
Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited
Legacy Keywords
ajo, american journal of orthopedics, total hip arthroplasty, tha, ceramic, United States, US, ceramic-on-ceramic, polyethylene, alumina, bearings
Legacy Keywords
ajo, american journal of orthopedics, total hip arthroplasty, tha, ceramic, United States, US, ceramic-on-ceramic, polyethylene, alumina, bearings
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Hyponatremia After Primary Hip and Knee Arthroplasty: Incidence and Associated Risk Factors

Article Type
Changed
Display Headline
Hyponatremia After Primary Hip and Knee Arthroplasty: Incidence and Associated Risk Factors

Article PDF
Author and Disclosure Information

Alexander P. Sah, MD

Issue
The American Journal of Orthopedics - 43(4)
Publications
Topics
Page Number
E69-E73
Legacy Keywords
ajo, american journal of orthopedics, online exclusive, study, hyponatremia, hip arthroplasty, knee arthroplasty, hip, knee, arthroplasty, risk factors, complications
Sections
Author and Disclosure Information

Alexander P. Sah, MD

Author and Disclosure Information

Alexander P. Sah, MD

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 43(4)
Issue
The American Journal of Orthopedics - 43(4)
Page Number
E69-E73
Page Number
E69-E73
Publications
Publications
Topics
Article Type
Display Headline
Hyponatremia After Primary Hip and Knee Arthroplasty: Incidence and Associated Risk Factors
Display Headline
Hyponatremia After Primary Hip and Knee Arthroplasty: Incidence and Associated Risk Factors
Legacy Keywords
ajo, american journal of orthopedics, online exclusive, study, hyponatremia, hip arthroplasty, knee arthroplasty, hip, knee, arthroplasty, risk factors, complications
Legacy Keywords
ajo, american journal of orthopedics, online exclusive, study, hyponatremia, hip arthroplasty, knee arthroplasty, hip, knee, arthroplasty, risk factors, complications
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Metallosis After Metal-on-Polyethylene Total Hip Arthroplasty

Article Type
Changed
Display Headline
Metallosis After Metal-on-Polyethylene Total Hip Arthroplasty

Article PDF
Author and Disclosure Information

Cara A. Cipriano, BA, Paul S. Issack, MD, PhD, Burak Beksaç, MD,
Alejandro González Della Valle, MD, Thomas P. Sculco, MD, and Eduardo A. Salvati, MD


Ms. Cipriano is Medical Student, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania.

Dr. Issack is Fellow, Adult Reconstructive Surgery and Orthopaedic Trauma, Dr. Beksaç is Research Fellow, Adult Reconstructive Surgery, Dr. González Della Valle is Assistant Attending Orthopaedic Surgeon, Dr. Sculco is Surgeon in Chief, Department of Orthopaedic Surgery, and Dr. Salvati is Director, Hip and Knee Service, Hospital for Special Surgery, New York, New York.

Issue
The American Journal of Orthopedics - 37(2)
Publications
Topics
Page Number
E18-E25
Legacy Keywords
ajo, american journal of orthopedics, metallosis, total hip arthroplasty, tha, metal on polyethylene,
Sections
Author and Disclosure Information

Cara A. Cipriano, BA, Paul S. Issack, MD, PhD, Burak Beksaç, MD,
Alejandro González Della Valle, MD, Thomas P. Sculco, MD, and Eduardo A. Salvati, MD


Ms. Cipriano is Medical Student, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania.

Dr. Issack is Fellow, Adult Reconstructive Surgery and Orthopaedic Trauma, Dr. Beksaç is Research Fellow, Adult Reconstructive Surgery, Dr. González Della Valle is Assistant Attending Orthopaedic Surgeon, Dr. Sculco is Surgeon in Chief, Department of Orthopaedic Surgery, and Dr. Salvati is Director, Hip and Knee Service, Hospital for Special Surgery, New York, New York.

Author and Disclosure Information

Cara A. Cipriano, BA, Paul S. Issack, MD, PhD, Burak Beksaç, MD,
Alejandro González Della Valle, MD, Thomas P. Sculco, MD, and Eduardo A. Salvati, MD


Ms. Cipriano is Medical Student, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania.

Dr. Issack is Fellow, Adult Reconstructive Surgery and Orthopaedic Trauma, Dr. Beksaç is Research Fellow, Adult Reconstructive Surgery, Dr. González Della Valle is Assistant Attending Orthopaedic Surgeon, Dr. Sculco is Surgeon in Chief, Department of Orthopaedic Surgery, and Dr. Salvati is Director, Hip and Knee Service, Hospital for Special Surgery, New York, New York.

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 37(2)
Issue
The American Journal of Orthopedics - 37(2)
Page Number
E18-E25
Page Number
E18-E25
Publications
Publications
Topics
Article Type
Display Headline
Metallosis After Metal-on-Polyethylene Total Hip Arthroplasty
Display Headline
Metallosis After Metal-on-Polyethylene Total Hip Arthroplasty
Legacy Keywords
ajo, american journal of orthopedics, metallosis, total hip arthroplasty, tha, metal on polyethylene,
Legacy Keywords
ajo, american journal of orthopedics, metallosis, total hip arthroplasty, tha, metal on polyethylene,
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Re-examining the Safety Issues of Ceramic-on-Ceramic Bearing Surface

Article Type
Changed
Display Headline
Re-examining the Safety Issues of Ceramic-on-Ceramic Bearing Surface

In this month’s E-publishing section, we will read more interesting and clinically pertinent articles, including an article by Tateiwa and colleagues on “Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited.”

The article, by a group of internationally recognized investigators, attempts, and accomplishes, a summary of the safety of alumina ceramic-on-ceramic bearing surface for use in THA. The main emphasis of the article is to highlight the findings of reports in the United States regarding the safety of the ceramic-on-ceramic bearing surface in general and the risk of fracture in particular.

That the article is well written and elegantly organized is not to be disputed. That the article presents the findings of various publications in an unbiased fashion is also not to be doubted. The authors nicely convince the reader that the ceramic-on-ceramic bearing surface is an important part of the armamentarium at the disposal of orthopedic surgeons who surgically treat arthritis of the hip in the young, and hence it is here to stay. I hope the authors will forgive me if I present the argument from a different and less “pro-ceramic” perspective.

First, the authors are, in my opinion, a little unfair and somewhat dramatic in their view on the conventional polyethylene and its new sister, the highly cross-linked polyethylene. I quote the authors: “In the past, however, clinical experience with ‘new and improved’ polyethylenes has seldom been exemplary, and current clinical experience is but a blip on the radar screen. It is also likely that the adverse conditions in the hips of our high-activity patients will severely challenge even the newest cross-linked polyethylene cups.” We all know conventional polyethylene
needed improvement. It did, however, serve hundreds of thousands of young patients very well without having any of the “problems” of the modern-day ceramic. The highly cross-linked polyethylene goes further in helping all patients, including the young ones. The “blips on the radar” are adding up as more investigators report their favorable experience with the highly cross-linked polyethylene.

I have another bone to pick with the authors. What happened to the other problems and “safety hazards” of ceramic-on-ceramic? The authors make no mention of the recent and not so infrequent problem with squeaking! Although some may brush the latter aside as mere “noise,” patients experiencing the
problem see it otherwise! In fact, some of these patients are so disheartened
by the problem that they heed the call of lawyers to go after the industry for “mis-manufacturing” these components. The problem is not so infrequent. According to a questionnaire survey by Dr. Ranawat, up to 4% of patients
reported squeaking of ceramic-on-ceramic hips. Our center, the Rothman Institute, has detected a 2% incidence of squeaking with the modern generation of ceramic-on-ceramic bearing surfaces. What is most disturbing is that the etiology of this noise-generating problem remains elusive.

Although the quoted figures for fracture of modern design ceramic heads are based on the available literature and are correct, some surgeons may feel that they are
an underestimation. I am sure the authors have, since the submission of their paper, seen the most recent article from Korea that reports a 1.4% incidence of fracture of femoral heads made of third-generation ceramic.

So, as a surgeon who believes in the incredible marvel of ceramic-on-ceramic bearing surface in substantially reducing wear, I merely want to say that ceramic-on-ceramic is not without its problems either. Depending on one’s viewpoint, one bearing surface may be better than another. One thing that remains certain is that the perfect bearing surface is still the articular cartilage. Regardless of how hard we try, we will never be able to emulate the Almighty. 

Article PDF
Author and Disclosure Information

Javad Parvizi, MD

Dr. Parvizi is Associate Professor of Orthopedic Surgery, Rothman Institute of
Orthopedics, Thomas Jefferson University, Philadelphia, Pennsylvania.

Issue
The American Journal of Orthopedics - 37(2)
Publications
Topics
Page Number
E17
Legacy Keywords
ajo, american journal of orthopedics, ceramic, total hip arthroplasty, tha, ceramic-on-ceramic, bearing surface, polyethylene
Sections
Author and Disclosure Information

Javad Parvizi, MD

Dr. Parvizi is Associate Professor of Orthopedic Surgery, Rothman Institute of
Orthopedics, Thomas Jefferson University, Philadelphia, Pennsylvania.

Author and Disclosure Information

Javad Parvizi, MD

Dr. Parvizi is Associate Professor of Orthopedic Surgery, Rothman Institute of
Orthopedics, Thomas Jefferson University, Philadelphia, Pennsylvania.

Article PDF
Article PDF

In this month’s E-publishing section, we will read more interesting and clinically pertinent articles, including an article by Tateiwa and colleagues on “Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited.”

The article, by a group of internationally recognized investigators, attempts, and accomplishes, a summary of the safety of alumina ceramic-on-ceramic bearing surface for use in THA. The main emphasis of the article is to highlight the findings of reports in the United States regarding the safety of the ceramic-on-ceramic bearing surface in general and the risk of fracture in particular.

That the article is well written and elegantly organized is not to be disputed. That the article presents the findings of various publications in an unbiased fashion is also not to be doubted. The authors nicely convince the reader that the ceramic-on-ceramic bearing surface is an important part of the armamentarium at the disposal of orthopedic surgeons who surgically treat arthritis of the hip in the young, and hence it is here to stay. I hope the authors will forgive me if I present the argument from a different and less “pro-ceramic” perspective.

First, the authors are, in my opinion, a little unfair and somewhat dramatic in their view on the conventional polyethylene and its new sister, the highly cross-linked polyethylene. I quote the authors: “In the past, however, clinical experience with ‘new and improved’ polyethylenes has seldom been exemplary, and current clinical experience is but a blip on the radar screen. It is also likely that the adverse conditions in the hips of our high-activity patients will severely challenge even the newest cross-linked polyethylene cups.” We all know conventional polyethylene
needed improvement. It did, however, serve hundreds of thousands of young patients very well without having any of the “problems” of the modern-day ceramic. The highly cross-linked polyethylene goes further in helping all patients, including the young ones. The “blips on the radar” are adding up as more investigators report their favorable experience with the highly cross-linked polyethylene.

I have another bone to pick with the authors. What happened to the other problems and “safety hazards” of ceramic-on-ceramic? The authors make no mention of the recent and not so infrequent problem with squeaking! Although some may brush the latter aside as mere “noise,” patients experiencing the
problem see it otherwise! In fact, some of these patients are so disheartened
by the problem that they heed the call of lawyers to go after the industry for “mis-manufacturing” these components. The problem is not so infrequent. According to a questionnaire survey by Dr. Ranawat, up to 4% of patients
reported squeaking of ceramic-on-ceramic hips. Our center, the Rothman Institute, has detected a 2% incidence of squeaking with the modern generation of ceramic-on-ceramic bearing surfaces. What is most disturbing is that the etiology of this noise-generating problem remains elusive.

Although the quoted figures for fracture of modern design ceramic heads are based on the available literature and are correct, some surgeons may feel that they are
an underestimation. I am sure the authors have, since the submission of their paper, seen the most recent article from Korea that reports a 1.4% incidence of fracture of femoral heads made of third-generation ceramic.

So, as a surgeon who believes in the incredible marvel of ceramic-on-ceramic bearing surface in substantially reducing wear, I merely want to say that ceramic-on-ceramic is not without its problems either. Depending on one’s viewpoint, one bearing surface may be better than another. One thing that remains certain is that the perfect bearing surface is still the articular cartilage. Regardless of how hard we try, we will never be able to emulate the Almighty. 

In this month’s E-publishing section, we will read more interesting and clinically pertinent articles, including an article by Tateiwa and colleagues on “Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited.”

The article, by a group of internationally recognized investigators, attempts, and accomplishes, a summary of the safety of alumina ceramic-on-ceramic bearing surface for use in THA. The main emphasis of the article is to highlight the findings of reports in the United States regarding the safety of the ceramic-on-ceramic bearing surface in general and the risk of fracture in particular.

That the article is well written and elegantly organized is not to be disputed. That the article presents the findings of various publications in an unbiased fashion is also not to be doubted. The authors nicely convince the reader that the ceramic-on-ceramic bearing surface is an important part of the armamentarium at the disposal of orthopedic surgeons who surgically treat arthritis of the hip in the young, and hence it is here to stay. I hope the authors will forgive me if I present the argument from a different and less “pro-ceramic” perspective.

First, the authors are, in my opinion, a little unfair and somewhat dramatic in their view on the conventional polyethylene and its new sister, the highly cross-linked polyethylene. I quote the authors: “In the past, however, clinical experience with ‘new and improved’ polyethylenes has seldom been exemplary, and current clinical experience is but a blip on the radar screen. It is also likely that the adverse conditions in the hips of our high-activity patients will severely challenge even the newest cross-linked polyethylene cups.” We all know conventional polyethylene
needed improvement. It did, however, serve hundreds of thousands of young patients very well without having any of the “problems” of the modern-day ceramic. The highly cross-linked polyethylene goes further in helping all patients, including the young ones. The “blips on the radar” are adding up as more investigators report their favorable experience with the highly cross-linked polyethylene.

I have another bone to pick with the authors. What happened to the other problems and “safety hazards” of ceramic-on-ceramic? The authors make no mention of the recent and not so infrequent problem with squeaking! Although some may brush the latter aside as mere “noise,” patients experiencing the
problem see it otherwise! In fact, some of these patients are so disheartened
by the problem that they heed the call of lawyers to go after the industry for “mis-manufacturing” these components. The problem is not so infrequent. According to a questionnaire survey by Dr. Ranawat, up to 4% of patients
reported squeaking of ceramic-on-ceramic hips. Our center, the Rothman Institute, has detected a 2% incidence of squeaking with the modern generation of ceramic-on-ceramic bearing surfaces. What is most disturbing is that the etiology of this noise-generating problem remains elusive.

Although the quoted figures for fracture of modern design ceramic heads are based on the available literature and are correct, some surgeons may feel that they are
an underestimation. I am sure the authors have, since the submission of their paper, seen the most recent article from Korea that reports a 1.4% incidence of fracture of femoral heads made of third-generation ceramic.

So, as a surgeon who believes in the incredible marvel of ceramic-on-ceramic bearing surface in substantially reducing wear, I merely want to say that ceramic-on-ceramic is not without its problems either. Depending on one’s viewpoint, one bearing surface may be better than another. One thing that remains certain is that the perfect bearing surface is still the articular cartilage. Regardless of how hard we try, we will never be able to emulate the Almighty. 

Issue
The American Journal of Orthopedics - 37(2)
Issue
The American Journal of Orthopedics - 37(2)
Page Number
E17
Page Number
E17
Publications
Publications
Topics
Article Type
Display Headline
Re-examining the Safety Issues of Ceramic-on-Ceramic Bearing Surface
Display Headline
Re-examining the Safety Issues of Ceramic-on-Ceramic Bearing Surface
Legacy Keywords
ajo, american journal of orthopedics, ceramic, total hip arthroplasty, tha, ceramic-on-ceramic, bearing surface, polyethylene
Legacy Keywords
ajo, american journal of orthopedics, ceramic, total hip arthroplasty, tha, ceramic-on-ceramic, bearing surface, polyethylene
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

A Multidisciplinary Total Hip Arthroplasty Protocol With Accelerated Postoperative Rehabilitation: Does the Patient Benefit?

Article Type
Changed
Display Headline
A Multidisciplinary Total Hip Arthroplasty Protocol With Accelerated Postoperative Rehabilitation: Does the Patient Benefit?

Article PDF
Author and Disclosure Information

Claire E. Robbins, PT, DPT, Daniel Casey, PT, James V. Bono, MD, Stephen B. Murphy, MD, Carl T. Talmo, MD, and Daniel M. Ward, MD

Issue
The American Journal of Orthopedics - 43(4)
Publications
Topics
Page Number
178-181
Legacy Keywords
ajo, american journal of orthopedics, study, total hip arthroplasty, THA, patient, rehabilitation, rehab, benefit, arthroplasty, hip, surgery, reconstruction
Sections
Author and Disclosure Information

Claire E. Robbins, PT, DPT, Daniel Casey, PT, James V. Bono, MD, Stephen B. Murphy, MD, Carl T. Talmo, MD, and Daniel M. Ward, MD

Author and Disclosure Information

Claire E. Robbins, PT, DPT, Daniel Casey, PT, James V. Bono, MD, Stephen B. Murphy, MD, Carl T. Talmo, MD, and Daniel M. Ward, MD

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 43(4)
Issue
The American Journal of Orthopedics - 43(4)
Page Number
178-181
Page Number
178-181
Publications
Publications
Topics
Article Type
Display Headline
A Multidisciplinary Total Hip Arthroplasty Protocol With Accelerated Postoperative Rehabilitation: Does the Patient Benefit?
Display Headline
A Multidisciplinary Total Hip Arthroplasty Protocol With Accelerated Postoperative Rehabilitation: Does the Patient Benefit?
Legacy Keywords
ajo, american journal of orthopedics, study, total hip arthroplasty, THA, patient, rehabilitation, rehab, benefit, arthroplasty, hip, surgery, reconstruction
Legacy Keywords
ajo, american journal of orthopedics, study, total hip arthroplasty, THA, patient, rehabilitation, rehab, benefit, arthroplasty, hip, surgery, reconstruction
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Nationwide Trends in Total Shoulder Arthroplasty and Hemiarthroplasty for Osteoarthritis

Article Type
Changed
Display Headline
Nationwide Trends in Total Shoulder Arthroplasty and Hemiarthroplasty for Osteoarthritis

Article PDF
Author and Disclosure Information

David Trofa, MD, Sean S. Rajaee, MD, and Eric L. Smith, MD

Issue
The American Journal of Orthopedics - 43(4)
Publications
Topics
Page Number
166-172
Legacy Keywords
ajo, american journal of orthopedics, study, nation, trends, nationwide, arthroplasty, total shoulder arthroplasty, TSA, hemiarthroplasty, HA, osteoarthritis, shoulder, patients, population, trofa, reajaee, smith
Sections
Author and Disclosure Information

David Trofa, MD, Sean S. Rajaee, MD, and Eric L. Smith, MD

Author and Disclosure Information

David Trofa, MD, Sean S. Rajaee, MD, and Eric L. Smith, MD

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 43(4)
Issue
The American Journal of Orthopedics - 43(4)
Page Number
166-172
Page Number
166-172
Publications
Publications
Topics
Article Type
Display Headline
Nationwide Trends in Total Shoulder Arthroplasty and Hemiarthroplasty for Osteoarthritis
Display Headline
Nationwide Trends in Total Shoulder Arthroplasty and Hemiarthroplasty for Osteoarthritis
Legacy Keywords
ajo, american journal of orthopedics, study, nation, trends, nationwide, arthroplasty, total shoulder arthroplasty, TSA, hemiarthroplasty, HA, osteoarthritis, shoulder, patients, population, trofa, reajaee, smith
Legacy Keywords
ajo, american journal of orthopedics, study, nation, trends, nationwide, arthroplasty, total shoulder arthroplasty, TSA, hemiarthroplasty, HA, osteoarthritis, shoulder, patients, population, trofa, reajaee, smith
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Wichita Fusion Nail for Patients With Failed Total Knee Arthroplasty and Active Infection

Article Type
Changed
Display Headline
Wichita Fusion Nail for Patients With Failed Total Knee Arthroplasty and Active Infection

Article PDF
Author and Disclosure Information

Wael K. Barsoum, MD, Christopher Hogg, DO, Viktor Krebs, MD, and Alison K. Klika, MS
Dr. Barsoum is a Staff Surgeon and Vice Chairman of the Department of Orthopaedic Surgery, Department of Orthopaedic Surgery, Dr. Hogg was a Fellow in the section of Adult Reconstruction at the time of manuscript preparation, Dr. Krebs is a Staff Surgeon and the Section Head of Adult Reconstruction, and Ms. Klika is a Research Coordinator, Cleveland Clinic, Cleveland, Ohio.

Issue
The American Journal of Orthopedics - 37(1)
Publications
Topics
Page Number
E6-E10
Legacy Keywords
ajo, american journal of orthopedics, infection, infectious disease, wichita fusion nail, total knee arthroplasty, tka
Sections
Author and Disclosure Information

Wael K. Barsoum, MD, Christopher Hogg, DO, Viktor Krebs, MD, and Alison K. Klika, MS
Dr. Barsoum is a Staff Surgeon and Vice Chairman of the Department of Orthopaedic Surgery, Department of Orthopaedic Surgery, Dr. Hogg was a Fellow in the section of Adult Reconstruction at the time of manuscript preparation, Dr. Krebs is a Staff Surgeon and the Section Head of Adult Reconstruction, and Ms. Klika is a Research Coordinator, Cleveland Clinic, Cleveland, Ohio.

Author and Disclosure Information

Wael K. Barsoum, MD, Christopher Hogg, DO, Viktor Krebs, MD, and Alison K. Klika, MS
Dr. Barsoum is a Staff Surgeon and Vice Chairman of the Department of Orthopaedic Surgery, Department of Orthopaedic Surgery, Dr. Hogg was a Fellow in the section of Adult Reconstruction at the time of manuscript preparation, Dr. Krebs is a Staff Surgeon and the Section Head of Adult Reconstruction, and Ms. Klika is a Research Coordinator, Cleveland Clinic, Cleveland, Ohio.

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 37(1)
Issue
The American Journal of Orthopedics - 37(1)
Page Number
E6-E10
Page Number
E6-E10
Publications
Publications
Topics
Article Type
Display Headline
Wichita Fusion Nail for Patients With Failed Total Knee Arthroplasty and Active Infection
Display Headline
Wichita Fusion Nail for Patients With Failed Total Knee Arthroplasty and Active Infection
Legacy Keywords
ajo, american journal of orthopedics, infection, infectious disease, wichita fusion nail, total knee arthroplasty, tka
Legacy Keywords
ajo, american journal of orthopedics, infection, infectious disease, wichita fusion nail, total knee arthroplasty, tka
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Infection Prevention in Total Knee and Total Hip Arthroplasties

Article Type
Changed
Display Headline
Infection Prevention in Total Knee and Total Hip Arthroplasties

Article PDF
Author and Disclosure Information

Mark Kuper, DO, and Alexander Rosenstein, MD

Dr. Kuper is Resident Physician, Department of Orthopaedic Surgery, Texas Tech University Health Sciences Center, Lubbock, Texas.

Dr. Rosenstein is Professor and Chief, Division of Adult Reconstruction, Department of Orthopaedic Surgery, University of Texas Health Science Center, Houston, Texas.

Issue
The American Journal of Orthopedics - 37(1)
Publications
Topics
Page Number
E2-E5
Legacy Keywords
ajo, american journal of orthopedics, infection, primary joint arthroplasty, total hip arthroplasty, tha, total knee arthroplasty, tka, antibiotic prophylaxis, antibiotics
Sections
Author and Disclosure Information

Mark Kuper, DO, and Alexander Rosenstein, MD

Dr. Kuper is Resident Physician, Department of Orthopaedic Surgery, Texas Tech University Health Sciences Center, Lubbock, Texas.

Dr. Rosenstein is Professor and Chief, Division of Adult Reconstruction, Department of Orthopaedic Surgery, University of Texas Health Science Center, Houston, Texas.

Author and Disclosure Information

Mark Kuper, DO, and Alexander Rosenstein, MD

Dr. Kuper is Resident Physician, Department of Orthopaedic Surgery, Texas Tech University Health Sciences Center, Lubbock, Texas.

Dr. Rosenstein is Professor and Chief, Division of Adult Reconstruction, Department of Orthopaedic Surgery, University of Texas Health Science Center, Houston, Texas.

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 37(1)
Issue
The American Journal of Orthopedics - 37(1)
Page Number
E2-E5
Page Number
E2-E5
Publications
Publications
Topics
Article Type
Display Headline
Infection Prevention in Total Knee and Total Hip Arthroplasties
Display Headline
Infection Prevention in Total Knee and Total Hip Arthroplasties
Legacy Keywords
ajo, american journal of orthopedics, infection, primary joint arthroplasty, total hip arthroplasty, tha, total knee arthroplasty, tka, antibiotic prophylaxis, antibiotics
Legacy Keywords
ajo, american journal of orthopedics, infection, primary joint arthroplasty, total hip arthroplasty, tha, total knee arthroplasty, tka, antibiotic prophylaxis, antibiotics
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Failure of the Vari-Angle Hip Screw System: Two Cases

Article Type
Changed
Display Headline
Failure of the Vari-Angle Hip Screw System: Two Cases

Article PDF
Author and Disclosure Information

Philip Daniel Nowicki, MD, and Gregory Minas Georgiadis, MD

Dr. Nowicki is Resident Physician, Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, Ohio.

Dr. Georgiadis is the Director of Orthopaedic Trauma Services at the Toledo Hospital, Toledo, Ohio.

Issue
The American Journal of Orthopedics - 37(11)
Publications
Topics
Page Number
575-576
Legacy Keywords
ajo, american journal of orthopedics, case report, screw, screw system, hip, cases, case, vari-angle, angle, failure, hip fractures, fracture, fixation
Sections
Author and Disclosure Information

Philip Daniel Nowicki, MD, and Gregory Minas Georgiadis, MD

Dr. Nowicki is Resident Physician, Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, Ohio.

Dr. Georgiadis is the Director of Orthopaedic Trauma Services at the Toledo Hospital, Toledo, Ohio.

Author and Disclosure Information

Philip Daniel Nowicki, MD, and Gregory Minas Georgiadis, MD

Dr. Nowicki is Resident Physician, Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, Ohio.

Dr. Georgiadis is the Director of Orthopaedic Trauma Services at the Toledo Hospital, Toledo, Ohio.

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 37(11)
Issue
The American Journal of Orthopedics - 37(11)
Page Number
575-576
Page Number
575-576
Publications
Publications
Topics
Article Type
Display Headline
Failure of the Vari-Angle Hip Screw System: Two Cases
Display Headline
Failure of the Vari-Angle Hip Screw System: Two Cases
Legacy Keywords
ajo, american journal of orthopedics, case report, screw, screw system, hip, cases, case, vari-angle, angle, failure, hip fractures, fracture, fixation
Legacy Keywords
ajo, american journal of orthopedics, case report, screw, screw system, hip, cases, case, vari-angle, angle, failure, hip fractures, fracture, fixation
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media

Arthroscopic Treatment of Femoroacetabular Impingement

Article Type
Changed
Display Headline
Arthroscopic Treatment of Femoroacetabular Impingement

Article PDF
Author and Disclosure Information

Thomas G. Sampson, MD

Dr. Sampson is Director of Hip Arthroscopy, Post Street Surgery Center, and Medical
Director, Total Joint Center, Saint Francis Memorial Hospital, San Francisco, California.

Issue
The American Journal of Orthopedics - 37(12)
Publications
Topics
Page Number
608-612
Legacy Keywords
ajo, american journal of orthopedics, treatment, arthroscopic, hip arthroscopy, impingement, femoroacetabular, FAI, 5 points, Sampson
Sections
Author and Disclosure Information

Thomas G. Sampson, MD

Dr. Sampson is Director of Hip Arthroscopy, Post Street Surgery Center, and Medical
Director, Total Joint Center, Saint Francis Memorial Hospital, San Francisco, California.

Author and Disclosure Information

Thomas G. Sampson, MD

Dr. Sampson is Director of Hip Arthroscopy, Post Street Surgery Center, and Medical
Director, Total Joint Center, Saint Francis Memorial Hospital, San Francisco, California.

Article PDF
Article PDF

Issue
The American Journal of Orthopedics - 37(12)
Issue
The American Journal of Orthopedics - 37(12)
Page Number
608-612
Page Number
608-612
Publications
Publications
Topics
Article Type
Display Headline
Arthroscopic Treatment of Femoroacetabular Impingement
Display Headline
Arthroscopic Treatment of Femoroacetabular Impingement
Legacy Keywords
ajo, american journal of orthopedics, treatment, arthroscopic, hip arthroscopy, impingement, femoroacetabular, FAI, 5 points, Sampson
Legacy Keywords
ajo, american journal of orthopedics, treatment, arthroscopic, hip arthroscopy, impingement, femoroacetabular, FAI, 5 points, Sampson
Sections
Article Source

PURLs Copyright

Inside the Article

Article PDF Media